CO2 Detector _CD-30M/I

CO2 Detector _CD-30M/I


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
co2 sensor, carbon dioxide detector, co2 detector _, ndir sensor
Category
Sensors
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

GasDNA

Membership
VIP
Country / Year Established
South Korea South Korea / 2004
Business type
Manufacturer
Verified Certificate

11

DUNS

Product name CO2 Detector _CD-30M/I Certification -
Category Sensors Ingredients -
Keyword co2 sensor , carbon dioxide detector , co2 detector _ , ndir sensor Unit Size -
Brand name - Unit Weigh -
origin Stock -
Supply type - HS code -

Product Information

◈ Introduction

CD-30M/30I are designed for air conditioning system being installed on air conditioning duct system. With built-in transmitter, CD-30M/30I can detect CO2 gas density using NDIR (Non Dispersive Infrared) and convert the measured density signal into linear current or voltage signal to be transmitted to external monitoring unit or controlling unit such as PLC or DDC.

 

◈ Sensor options


Measurement range 
0~2,000ppm /0~3,000ppmm/ 0~10,000ppm
 
◈ Specification
 
Mounting type                               Wall mounting or  duct mounting
Detection principle                        NDIR (Non-Dispersive Infrared)
Detection method                          Diffusion
Response time                              Within 20 seconds – 0.1 liter air flow / min.
Accuracy                                      ±1% / full scale, ±5% / reading
Zero variance                                 <±0.3% / full scale / year
Measurement range                       0~2,000ppm / 0~5,000ppm 

Output                                         4-20mA

D / A   resolution                           12bit
D / A  accuracy Voltage mode:       ±2% / reading ±20mV, current loop: ±2%

                                                   / reading ±0.3mA
Input power                                      24V AC/DC ±20%, 50~60Hz
Power consumption                           ≤3W
Signal wire                                       CVVS &  CVVSB 1.25sq X 3 wire – shield type
Terminal                                           Screw terminal
Housing                                            Metal case with metal tube
Operation temperature / humidity        0~50℃ / 0~95% RH (non-condensing)
Initialization time                               Within 1 min

 

Product Info Attached File

CD-30M & 30I.pdf

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

GasDNA

Country / Year Established
South Korea South Korea / 2004
Membership
VIP
Business type
Manufacturer

11

DUNS

President
GO SUNG-WOON
Address
C-910C, Bupyeong woolim lion's valley, cheongcheon-dong, Bupyeong Gu, Incheon, Korea
Product Category
Sensors,Smoke Detector,Temperature Instruments
Year Established
2004
No. of Total Employees
1-50
Company introduction

GasDNA Co.,Ltd is a professional and leading manufacturer of Fixed Infrared thermometers, Gas detectors and smoke detectors

for use in a various kinds of industries.

GasDNA is focusing on developing and distributing more convenient and stable gas detectors and infrared thermometers.

Based on the technologies and expertise accumulated for last 10 years, we have positioned as Korea's only infrared thermometer

manufacturer, and we are planning to expand into not only the domestic market but overseas markets.

We develop and manufacture efficient and reliable products based on state-of-the-art technologies, and we do our best to be the world's leading company in the gas detector and Infrared thermometer field.

We promise customer's safety and product quality in accordance with the quality assurance K mark and ISO9001 quality system to maximize the customer's use value.

 

Gas detectors detect one target combustible or toxic gas leaked from industrial sites for in order to prevent any accidents in advance. And it converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on. Using these functions, you can easily construct the gas monitoring system more extensive as well as more comprehensive.

Infrared thermometer measures a surface temperature by non-contact through measuring the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA) and RS-485 communication signal output. we have a various tempearture ranges upto 2400degreeC and compact and precision type, also can choose fixed and portable type.

Main Markets

Taiwan Taiwan

Factory Information

GasDNA

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more