Low Voltage Reactive Power Compensation

Low Voltage Reactive Power Compensation


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
China
Brand name
WORLDSURE
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
capacitor bank, low voltage electrical power system power saver, harmonic suppression, harmonic governance
Category
Electrical Equipment , Passive Components , Power Supplies , Industrial Power Supply , Voltage Regulators/Stabilizers
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

Worldwide Electric Stock Co., Ltd

Membership
PRO
Country / Year Established
China China /
Business type
Manufacturer
Verified Certificate

10

Product name Low Voltage Reactive Power Compensation Certification -
Category Electrical Equipment
Passive Components
Power Supplies
Industrial Power Supply
Voltage Regulators/Stabilizers
Ingredients -
Keyword capacitor bank , low voltage electrical power system power saver , harmonic suppression , harmonic governance Unit Size -
Brand name WORLDSURE Unit Weigh -
origin China Stock -
Supply type - HS code -

Product Information

 

WPGJ reactive power compensation capacitor

 

I. General

Most of the loads in electric power system are inductive which lead a low power factor. As an enterprise, for the requirement of the electricity, the lower of the power factor, the more capacity of the supply transformer in the condition of the same active power. This will increase the supply investment, and reduce the use factor of the equipments, as well as increase the network circuit lost which impairs the quality of the voltage. Thus, to improve the power factor is an important project for enterprises to save energy and to improve the quality of the electric network. Enterprises shall take some corresponding methods to improve the power factor. 

Reactive power compensation is necessary for the improvement of the power factor. The basic principle is to parallel connect the unit of capacitive power load to the inductive power load. While the capacitive load is releasing energy, the inductive load is absorbing it; while the inductive load is releasing energy, the capacitive load is absorbing it. That is, the energy is transformed in between the two loads and thus the reactive power received by the capacitive load is compensated by the reactive power released by the inductive load to reduce the absorption of the reactive power from the electric network.

There are many methods of the reactive power compensation, mainly as follows:

1. To use over-excitation synchronous motor. This method is of complex equipments and high cost, which is only workable when it is large power device drive

2. To use the phase adjuster as the power supply of the reactive power. This device is of good performance which can improve the stability of the electric power system, but it is of high cost, large investment, high consumption for about 1.8% to 5.5% power consumption per kilovar and complex operation technique.

3. To use static advancer to change the performance of the single motor, to reduce the reactive power and the temperature rise, to increase the output power, to improve the efficiency and to save the energy. But it only applies to wound-rotor motor. 

4. To synchronize the asynchronous motor. This method has a certain effect but it is with large self consumption for about 4% to 19% of the reactive power per kilovar, which is generally not adopted.

5. To use the power capacitor for compensating. This method is with convenient installation, short construction period, low cost, easy operation and maintenance and low self consumption for about 0.3% to 0.4% or below of the consumption per kilovar. 

There are two methods of the power capacitor as a compensating device:

1. Serial connecting compensation: that is, serially connect the power capacitor to the high voltage electric transmission line to improve the parameter of the electric transmission line, to lower the voltage lost, to increase the output capacity and to reduce the consumption of the circuit. This method is applicable to high voltage remote electric transmission and it is seldom adopted by the electricity enterprises.

2. Parallel connecting compensating: that is, parallel connect the capacitor and the compensating equipments to one circuit to improve the power factor. This compensation method is adopted by all the electricity enterprises.

The main functions of the parallel connecting capacitor compensating the reactive power are:

1. To compensate the reactive power and improve the power factor.

2. To increase the output capacity of the equipment.

3. To lower the energy consumption and the energy lost.

4. To improve the voltage quality.

For improving the electric network quality and other aspects of the enterprise, our company produced WPGJ low voltage reactive power automatic compensating parallel connecting capacitor complete equipment which can improve the power factor of the electric network automatically and increase the voltage quality of the network as well as lower the consumption of the power distribution system and the transformer.

 

 

III. Performance characteristic

1. Adopting self-healing capacitor whose performance is far better than oil medium power capacitor. The medium and the poles of the self-healing capacitor have self-healing performance. It is with high density of field, low consumption of the medium, small volume and large capacity.

2. An automatic controller of reactive power compensation has been set which can circulate automatically and switch the capacitor by steps. The switching time interval can be adjusted to keep the reactive power consumption of the electric network at the lowest level, in order to improve the quality of the network voltage efficiently and reduce the consumption of the power distribution system and the transformer.

3. Multiple protections: 

1). Single fuse protection

2). Over current protection

3). Over voltage protection

4). Under voltage protection

5). Inrush current and higher harmonic suppression

4. The power factor can be improved to 0.92 or above if the proper capacity is adopted.

 

VI. Applications 

1. The power factor in the enterprise is low and often fined by the supply apartment. The power factor needs to be improved.

2. The voltage of the enterprise substation is low. The voltage of the electric network needs to be increased.

3. The wire lost of the enterprise is too much and it needs to be reduced.

4. Electricity equipments put into use lately.

5. The old capacitors need to be replaced.

 

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Worldwide Electric Stock Co., Ltd

Country / Year Established
China China /
Membership
PRO
Business type
Manufacturer

10

President
Shiyun Zhao
Address
No.58, Changzheng Road, Xiangyang City, Hubei Province, China
Company introduction

 

Worldwide Electric Stock Co., LTD,one of the biggest electrical control equipment manufacture in China,established in the year 2000, more than 1000 employees, with 60000 square meter workshop. It is not only an enterprise that grows fast and has the strongest competitiveness in the electric motor soft start field, but also has become a well-known brand enterprise in motor control and energy saving, automation of electric power systems (high/low pressure switch complete control system) and energy saving field.

 

Our products are widely used in building materials, chemical industry, metallurgy, mining, machinery, automobile, municipal, electric power, household appliances, and many other industries. The sales network has been throughout each province, and municipality and with a turnover of 70 million yuan. There are our customers all around the mainland of China. Some of our products have been exported to more than twenty foreign countries. Such as: RussiaEgyptBrazilArgentinaIranSaudi ArabiaVietnamBurmaBangladeshThailandPhilippines and so on.

 

Our main products are as followings:

1) 240V to 35KV switchgear cabinet
2) 5.5KW to 40000KW motor soft starter 
3) AC/ DC motor speed controller
4) reactive power compensation /power factor correction device
5) high /low voltage motor power saver ,electric power saver

6) transformer substation

7intelligent optimization power distribution network power saving system

8) lead-acid battery chemical charge and discharge machine

9) high voltage AC vacuum contactor 

 

 

 

We have formed a strong technology advantages and competitiveness in the two areas of “motor control and energy saving” and “power system automation and energy saving”. Our products are widely used in every corner of China and in more than thirty foreign countries.

 

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more