40km 35kv High Precision Cable Fault Locating System

40km 35kv High Precision Cable Fault Locating System


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
China
Brand name
Sansion Power
Payment Terms
D/A,D/P,L/C,T/T,Western Union
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
high precision cable fault locating system
Category
Other Measuring & Gauging
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

Sansion Power Electric Ltd. Co

Membership
BIZ
Country / Year Established
China China /
Business type
Manufacturer
Verified Certificate

9

Product name 40km 35kv High Precision Cable Fault Locating System Certification -
Category Other Measuring & Gauging Ingredients -
Keyword high precision cable fault locating system Unit Size -
Brand name Sansion Power Unit Weigh -
origin China Stock -
Supply type - HS code -

Product Information

 

Product Description
General Information:

SXDL-330 is applied for detecting the different cable faults including: open circuit broken fault, high impedance leakage and high impedance flash over fault. It's suitable for various 35KV and below copper aluminum core power cables, coaxial telecommunication cable, and local cable.
The system is including:
1.    SXDL-330 Cable Fault Tester 
2.    SXDL-330D Cable Fault Locator
3.     SXDL-330L Route Tracer
 Other accessories.


On Site Test




Features:
 

√  LCD screen.
√  Measuring mode: Low voltage pulse, impulse high voltage current sampling, DC high voltage flash over and etc.

√  High performance rechargeable battery, USB sampling port, could connect with laptop directly.
√  HV is fully isolated against operator and instrument, high anti-interference ability and safe reliability. 
√  The distance from test to failure location can be displayed directly.
√  Build in printer, test results and waveform can be stored automatically.
√  Full English interface, to display the test waveform clearly.
√  Windows system, easy to operate.
√  Double waveform track tracers, easy to compare and analyze the waveforms.

 SXDL-330 S Cable Fault Tester

Specification:
√  Test distance: 4m~40km
√  Test precision: Error is not larger than 1m measuring range < 1km.
          Relative error is not larger than 0.5%  measuring range > 1 km.
√ Pulse amplitude: no less than 250V 50Ω
√ Pulse width:  0.2μs, 2μs, 4μs
√ Sampling frequency: 48MHz, 24MHz, 12MHz, 6MHz
√ System Error: 10cm
√ Reading Frequency: V/2f  V is the electric wave's propagation velocity  in the cable (m/μs). f is sampling frequency (MHz). For example the oil-paper cable's propagation velocity is V=160m/μs, f=40MHz sampling, the reading frequency is 160/(2×40)=2m.
√ Presetting 5 types electric wave's propagation velocity of cable medium:
l   Oil-paper: 160m/μs
l   XLPE: 172m/μs
l   PVC: 184m/μs
l   Rubber Cables for Coal Mine: 100m/μs
l   Others non-power cable's propagation velocity of electric wave are settable. (Medium is at user's option)
√ Sampling: Current sampling method.
√ Power Supply: Power frequency or build-in rechargeable battery.
√ Power frequency: AC 220V±10%, frequency 50Hz±5%, 24 hours continuously working.
√ Battery: 4 hours continuously working.
√ Working temperature: -10ºC~50ºC
√ Oversize: (L×W×H)  330×230×150mm
√ Weight: 3kg. SXDL-330D Digital Cable Fault LocatorIt's used to locate the power cable insulated fault point, route, depth accurately, .
Specification:
√  Digital display distance: Max. 500m, Min. 0.1m.
√  Rough test error is less than 10%, locating error is 0.
√  Electromagnetic channel gain>110dB (300 thousand times)
√  Electromagnetic channel receiver sensitivity <5μV
Audio channel frequency amplifier <120dB  SNR (Signal to Noise Ratio) is 100 times when  4:1.
√  50Hz power frequency inhibition degree >40dB (100 times)
√  Audio & electric synchronous display: when do the locating test on site , the digital screen to repeat counting one time under the shocking of electromagnetic which formed by pulse high voltage. And to display the fault distance or fully lighted (500m). The high impedance earphone could detect the seismic wave generated by impulsive discharging breakdown.
√  To change the sound wave sensor probe to the 15KHz electromagnetic one, it could be used as accurate cable route and depth detecting test.
√  Power supply: 6V maintenance-free battery 1.2AH.
√  Power consumption: <120mA (0.7W)
√  Working temperature: -10ºC~+50ºC RH 80%. SXDL-330L Route Tracer
Route tracing signal source, to be equipped with locator to find the route of underground cable.
√  Output power: ≥30W when the load resistance is 10Ω, and adjustable continuously.
√  Signal frequency: 15KHZ
√  Working duty: Continuous (duty cycle 1Hz/sec), Uniform amplitude, amplitude modulation (modulation frequency 400-1000Hz).
√  Over heated, over load protection, 8 hours continuously working.√  Over heated, over load protection, 8 hours continuously working.
√  Power Supply: 220V 
√  Working temperature: -20ºC~+50ºC RH<95%.

 

Warranty: One year quality guarantee after shipment.


Please kindly contact with us for further information. 
 

 

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options D/A,D/P,L/C,T/T,Western Union Shipping time Negotiable

Sansion Power Electric Ltd. Co

Country / Year Established
China China /
Membership
BIZ
Business type
Manufacturer

9

President
Miss Ying
Address
F/4 Building 8, YuanYuanXin Industrial Park, No. 8 HuanHu Middle Road, DongXiHu District, Wuhan, China.
Product Category
Testing Equipment
No. of Total Employees
1-50
Company introduction

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment protection, water conservancy, petrochemical industry, aerospace and etc. 

Main products: 

HV Hipot Test Set System 

Transformer Test Equipment 

HV Switchgear Test Set 

Relay Protection Tester 

CT/PT Tester 

SF6/Oil Tester 

Transmission Line Test System 

Insulation Resistance Tester 

Earth Resistance Tester 

Sansion Power Electric contains R&D department, instruments manufacturing workshop, HV workshop, sample exhibition room, HV testing laboratory, quality control department, general office, sales departments, information office and etc, now we have more than 80 employees including 20 technical engineers. We have obtained the ISO9001 quality system certification and all products strictly conform to the international IEC or Chinese state standards. 

Sansion Power has three subsidiaries companies: 

Sansion Power Electric Co., Ltd. (R&D, manufacturing, marketing) 

Sansion Power Electric Engineering Co., Ltd. (Electrical installation, laboratory construction, on-site service) 

Sansion Power Electric Equipment Rental Co., Ltd. (Power electrical testing products rental and service) 

From the date of order placing, we usually need 3-7 working days to manufacturing. Located in Wuhan City, the provincial capital of China, Sansion Power is easy to ship the package by the air or ocean. Sansion Power also can provide OEM service according your customized. We are sincerely looking forward to cooperate with you from all the countries of the whole world. 

Sansion History 

Nov. 2013 Sansion Power Electric Engineering Co., Ltd. And Sansion Power Electric Equipment Rental Co., Ltd. Established. 

Oct. 2012 800kVA/800kV SXBP Series Variable Frequency AC Resonance Test System exported to National Power Company of Yemen. 

Mar. 2012 Launch of Intelligent Wireless HV Hipot Test Set, realized the first paperless testing in the domestic power electric field. 

DEC. 2011 Launch of SXI-16 Composite Insulator Faults Detector. 

Oct. 2011 Certificate ISO9000-2008. 

Oct. 2010 Launch of SXI-18 Intelligent Insulator Faults Detector. 

Aug. 2009 Full set of test equipment for 35KV substation exported to Kenya. 

Apr. 2008 Sales and technical support offices are maintained across several provinces in China, realize domestic sales & after sales service network. 

Mar. 2007 Special R&D department founded, and launch of 300kVA SXBP Series Variable Frequency AC Resonance Test System. 

Oct. 2006 First sale to foreign country: High-voltage test equipments exported to Russia. 

Feb. 2006 Certificate ISO9000-2001. 

DEC. 2005 Launch of 500kV Insulator Faults Detector. 

May. 2005 Sansion Power Electric Co. Ltd. Established. 

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more