본문으로 바로가기
Product Thumnail Image

Automation Heating

Negotiable | Min. Order

Description
Special Feature of Automated Heating Fuel Saving-Rooms not in use can be controlled easily. Convenience-Room temperatures can be controlled as desired. Compatibility-Can be installed in any kind of boiler. Rupture Prevention-When room temperature is less than 5 dg. C, run the boiler and prevent rupture. Where to use-Apartment units, housing, motels, officetel, buildings and boarding houses. Heat Source-District heating, central heating, gas boiler, solar heat and oil fired boiler. Static Signal : Red(+), Black(-) →CLOSEReverse Signal : Red(-), Black(+) →OPENModel : AT12-2T, A212-2T, A312-2T(DC 12V). AT24-2T, A224-2T, A324-2T(DC 24V) Switch : ON →OPEN, OFF →CLOSEModel : AT12-3T, A212-3T, A312-3T(DC 12V), AT24-3T, A224-3T, A324-3T(DC 24V) Static Signal : Red(+), Black(-) →CLOSEReverse Signal : Red(-), Black(+) →OPENModel : AT12-50(DC 12V), AT24-50(DC 24V) Static Signal : Red(+), Black(-) →OPENReverse Signal : Red(-), Black(+) →OPENModel : AT24-20(DC 24V)*Close : Manual Black (T-Phase) →CLOSECommon : Red (R Phase) +White (T-Phase) →OPENModel : AT220-50(AC 220V) On signal of Controller(Current control) →OPENOFF Signal (Current Control) →CLOSEModel : AT220-40P(AC 220V) Applicable to apartment units, villa, housing, studios, motels and boarding houses. The system is convenient to use and reduces heating energy by controlling valves according the temperature of each room and time. Application examples for apartment unit, villa and house Studio, motel, boarding house, hospital, pensionHeated water will be supplied only to the room in which the heating control panel switch is on and the room’s heat valve, open. This is controlled at the information desk when a customer checks in, allowing for pre-heating before customer check-in with an advanced bookings. After time has elapsed, the switch can be turned off and the heat valve, closed. The system can be controlled at the information desk, reducing heating energy by only activating heating when necessary.
TKPAY Sample
Samples INFO

Negotiable | (Min. Order)

Payment
  • visa
  • master
  • jcb
  • unionPay
  • 10 Valcon Co., Ltd.

    Supplier Activity

    Country South Korea South Korea

    Send Message
    PRODUCT DESCRIPTION
    COMPANY INFORMATION
    Product Information

    Special Feature of Automated Heating

    • Fuel Saving-Rooms not in use can be controlled easily.
    • Convenience-Room temperatures can be controlled as desired.
    • Compatibility-Can be installed in any kind of boiler.
    • Rupture Prevention-When room temperature is less than 5 dg. C, run the boiler and prevent rupture.
    • Where to use-Apartment units, housing, motels, officetel, buildings and boarding houses.
    • Heat Source-District heating, central heating, gas boiler, solar heat and oil fired boiler.
    Static Signal : Red(+), Black(-) →CLOSE
    Reverse Signal : Red(-), Black(+) →OPEN
    Model : AT12-2T, A212-2T, A312-2T(DC 12V). AT24-2T, A224-2T, A324-2T(DC 24V)
    Switch : ON →OPEN, OFF →CLOSE
    Model : AT12-3T, A212-3T, A312-3T(DC 12V), AT24-3T, A224-3T, A324-3T(DC 24V)
    Static Signal : Red(+), Black(-) →CLOSE
    Reverse Signal : Red(-), Black(+) →OPEN
    Model : AT12-50(DC 12V), AT24-50(DC 24V)
    Static Signal : Red(+), Black(-) →OPEN
    Reverse Signal : Red(-), Black(+) →OPEN
    Model : AT24-20(DC 24V)
    *Close : Manual
    Black (T-Phase) →CLOSE
    Common : Red (R Phase) +
    White (T-Phase) →OPEN
    Model : AT220-50(AC 220V)
    On signal of Controller(Current control) →OPEN
    OFF Signal (Current Control) →CLOSE
    Model : AT220-40P(AC 220V)

    Applicable to apartment units, villa, housing, studios, motels and boarding houses. The system is convenient to use and reduces heating energy by controlling valves according the temperature of each room and time.

    Application examples for apartment unit, villa and house

    Studio, motel, boarding house, hospital, pension
    Heated water will be supplied only to the room in which the heating control panel switch is on and the room’s heat valve, open. This is controlled at the information desk when a customer checks in, allowing for pre-heating before customer check-in with an advanced bookings. After time has elapsed, the switch can be turned off and the heat valve, closed. The system can be controlled at the information desk, reducing heating energy by only activating heating when necessary.

    Image
    Company

    Valcon Co., Ltd.

    Country South Korea South Korea

    Supplier Activity

    President
    Suckwon Song
    Address
    1730-4 Daeyun 1-dong, Nam-guBusan,
    Product Category
    Valves
    No. of Total Employees
    1-50
    Company introduction

    As a leader in energy-saving since its foundation in 1996, VALCON COMPANY LIMITED has played a pivotal and innovate role in the areas of fluid equipment control through the application of electric control ball valves in industrial machinery and equipment. While we keep faithful to principle, we will continue dedicating our best efforts to become a company that operates under comprehensive customer-oriented management. We never shy away from new challenges and will try our best to become a world-class firm through rational management as well as continued technological innovation. VALCON spares no effort in its quest to become a leader in its industry and to be recognized in the rapidly-changing world market for its product expertise. To realize this, all our staff will carry the VACON name with pride, seizing every opportunity in the dynamic world-market and creating a competitive edge unsurpassed among similar global enterprise. As a company of customer-centric business operations, we will grow with our customers in our constant pursuit of increased customer satisfaction through rigorous quality management.

    Other Products viewed with This Product