Product Information

Feature

  • Gross, net, weight batch count / gross, net/ gross and net
  • Temperature compensation to API Tables
  • gross or net scaled pulse output
  • Basic 1-channel(Option 2-Channel loading)
  • Dual data communication port with protocol matching
  • Fully isolated External Input and Output

Over View

The PCL600 Series batch controllers use temperature correction to calculate the volumetric flow for liquids at standard reference conditions. The PCL600 Series is ideally suited to custody transfer applications and includes the API/ASTM equations covering general petroleum products and LPG. The PCL600 Series is direct RTD input or 4-20mA temperature input.

General

Display Main : Large 2-line x 20-character LCD With LED B/L
Sub : Small 2-line x 20-character LCD With LED B/L
Display Update Rate 0.25-second
Decimal Points Fully programmable for Rate and Total
Time Base The Rate can be displayed in unit per second, per minute, per hour or per day
Data Retention Set up parameters and totals stored in non-volatile memory with 10 years retention
Operation Temperature -25°C to 60°C
Power AC110V/ 220V Selectable(50/60Hz)
Transducer Supply 12V or 24V selectable, 100mA max

Flow Inputs

Frequency(Pulse) Input
Number Of channel 2-Channel
Frequency Range 0.5 to 10 kHz Max
Signal Type open collector, reed switch, voltage and current pulse
K-factor Range 0.0001 - 50000.0000(the pulse per units)
Analog Input
Number Of channel 2-Channel
Inputs 4-20 mA or 1-5V option
Input Impedance Current 250 ohms
Voltage 10K ohms
Accuracy 0.05%
Span 0.0001 to 50000.0000
Zero 0.0000 to 50000.0000
Cut-off Point A low flow rate cut-off can be programmed below which flow is not registered. The cut-off is programmed as a percentage of span relationship Linear or square root.

Temperature Input

RTD Input
Number Of channel 2-Channel
Type Platinum PT100(DIN)
Temperature Range -100°C to +200°C(Refer to the ordering information for detail)
Accuracy 0.1°C
Linearity The non-linearity of the RTD is internally compensated for.
Analog Input
Number Of channel 2-Channel
Inputs Impedance 250 ohms
Measurement Range -100°C to +200°C
Accuracy 0.05%

Digital Input

Channel 6-Channel
Function Open collector Input
For External switch, Earth Device, Aux pulse input. etc
Pulse Width 10 ms(negative going pulse)
Nominal Input Voltage 12VDC
Maximum Input Voltage 12VDC

Valve Control Output

Function Two stage valve control
Digital valve control
Relay Type AC Solid-State-Relay or
Mechanical Contact-Relay
Load Voltage 90-240VAC or 250VAC/30VDC
Max. Current 1.5 Amps or 10A

4-20mA Output

Channel 2-Channel
Function Outputs flow rate in gross volume, net volume, mass or energy, The 4 and 20 mA points can be programmed to provide a fully scaled output.
Resolution 12-bit
Accuracy Better than 0.025%
Maximum Load 500 ohms internally powered. 950 ohms from external 24V dc.
Isolation Output is isolated.

RS232/422/485

Type Both RS232 and RS422/485 are provided.(Note : When using the RS422/485, multi drop communication can be implemented with up to 32 instruments connected to a common bus.
Communication Channel 2-Channel
Isolation Communication is optical isolation
Function Printer and computer protocols are fully programmable.
Printer A print is initiated on each reset or at a programmable time interval.
Computer An ASCII based protocol enable all display parameters to be read and the totals to be reset.
Baud Rate 1200 to 19200 BPS
Data Bit 8-bit
Parity Bit None
Time A real time clock is provided to give time and date on each output.

Digital Output

Function Open collector output with a pulse produced on each increment of the accumulated total(gross, net, mass or energy).
Pulse Width 10ms(negative going pulse)
Duty Cycle 49 pulses/sec. Max.
Channel 5-Channel
Output Current sinking output transistor 50ma, 30vdc max.(Pulse output is suitable for driving remote counter or PLC's)

Enclosure

Explosion proof
Outside Dimension 270mm(H) x 290mm(W) x 280(D)
Notice : H is not fixed
Mounting Dimension 90mm(H) x 83mm(W) x M8 Bolt
Classification

Division 1, Class I Group-A, B,C,D
Class II Group-E, F&G
ClassIII
Zone 1 or 2, Exd II B T6

Application

  • Truck Loading
  • Railcar Loading
  • Chemical Loading
  • LPG, Lube Oils
  • Barge Loading
  • Shipping Docks
  • Bulk plants

System

Modeling

MODEL Description
PCL600-           Petro loading Controller
Temperature N
A
R
        No Option
4-20mA Analog Temperature Input
Pt 100 Ohms RTD Input
Channel  

1
2

      One arm loading(STD)
Two arm loading(OPTION)
Analog Output     0
1
2
    No option
4-20mA output 1 channel
4-20mA output 2 channel
Case       E X

Explosion proof

Dimension

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Flos Korea

Country / Year Established
South Korea South Korea /
Business type
Others

15

DUNS

President
SHIN YI RAE
Address
#1119 Woolim Lions Valley II 680 Gasan-dong, Geumcheon-Gu, Seoul, Korea
Product Category
Wires & Cables
Company introduction

FLOS KOREA have been doing business for over 20 years as one of the leading
Manufacturers and exporters of Flow Instruments in Korea.

Korean Customers depend on FLOS KOREA for quality Flow Instruments products
Which are simple to operate, an generate reliable results for all their
Process requirements.
Sophisticated testing equipment ensures that every Flow controller, Flow Transmitter
and Flow Computer, Batch Controller manufactured meets our highest standards.

Engineered to provide reliable, accurate information, FLOS KOREA instrument are
Used in applications form Flow controller and Automate Factory.
We are also proud to offer easy-to-use instrumentation, ensuring simple installationAnd minimal maintenance.

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more