Product name | NIBP Blood Pressure Module | Certification | - |
---|---|---|---|
Category | Other Monitoring & Diagnostic Equipment | Ingredients | - |
Keyword | - | Unit Size | - |
Brand name | - | Unit Weigh | - |
origin | Stock | - | |
Supply type | - | HS code | - |
Product Information
Specification
Dimension ; 105.4 × 69.4 × 38mm(Width ×Length ×Height) Weight ; Appro. 150g Power Source ; DC from 6.0 to 15Volt ± 5% Power consumption ; Maximum12Watt, Typical 6Watt Measuring range SYSTOLIC of Blood Pressure Adult 40 – 270mmHg, Pediatric 40 – 150mmHg, Neonate 40 – 130mmHg MAP of Blood Pressure Adult 30 – 260mmHg, Pediatric 30 – 140mmHg, Neonate 30 – 120mmHg DIASTOLIC of Blood Pressure Adult 20 – 250mmHg, Pediatric 20 – 130mmHg, Neonate 20 – 110mmHg Pulse Rate 30 - 300bpm Measuring Accuracy Blood Pressure ±3mmHg between 0 mmHg and 300 mmHg for operating conditions between 0°C and 50°C. Pulse Rate ± 2% or ± 3 BPM, whichever is greater Initial Inflation Pressure Adult 180mmHg(Defualt), Variable 120-280mmHg Pediatric 130mmHg(Defualt), Variable 100-160mmHg Neonate 120mmHg(Defualt), Variable 80-140mmHg Startup Initialization Period ; 5 seconds
Interfacing
UART TTL/RS-232C Asynchronous Operation,Baud rate 9600bps,8 Data bit, 1 Stop bit, no parity bit
The Module meets all relevant parts of the following Safety Standards:
• IEC60601-1:1997
• IEC/EN60601-2-30:1999/2000
• AAMI SP10:1992/2002
• EN1060-1:1996
• EN1060-3:1997
B2B Trade
Price (FOB) | Negotiable | transportation | - |
---|---|---|---|
MOQ | Negotiable | Leadtime | Negotiable |
Payment Options | Negotiable | Shipping time | Negotiable |
- President
- shoon Han
- Address
- Noblesse201, Hanbat-daero138, Daejeon Korea
- Product Category
- Sensors
- No. of Total Employees
- 1-50
- Company introduction
-
President/owner shoon Han has founded APMKorea (Advanced Prime Materials) 9th, September 2008.
He has experience for 25years in semiconductor industry.Joined the member of the KITA (Korea International Trade Association) Register No. 16118892.
Shipped SPO2 blood sensor chips for medical device customers in Germany, India, Indonesia, Singapore, Turkey and Korea. June 2009~.Developed reflective blood sensor chips, providing new idea and varial applications for medical device customers in Singapore, Germany, Ukraine, India. March 2010~.
Joined New Exporters 300 as a member, consulted by KITA (Korea International Trade Association). 23rd March 2010.
Shipped SPO2 blood sensor chips for medical device customers in Switzerland and Brazil May 2010~.Registered a patent for the reflective blood sensor, 10-2010-0047289 20th May 2010.
Shipped SPO2 blood sensor chips for medical device customers in Colombia 20th May 2010~.
Presented at the Technology Road Show in Shanghai & Beijing China 6~10th Sep. 2010
Shipped Refective SPO2 blood sensor to Japan 15th Sep. 2010~.Shipped SPO2 blood sensor chips 8000pcs for medical device customers in Shanghai China Dec 3rd 2010~.
Shipped SPO2 blood sensor chips for medical device customers in Uruguay 11th Dec 2010~.
Shipped SPO2 blood sensor chips for medical device to India, Israel, Vietnam, US, New zealand, UK, France, Slovenia, Bulgaria, Italy 2011~.
Transmissive SpO2 Oximeter sensor qualified and supply to Germany June 2011~
Shipped SpO2 oximeter sensor to NASA (Johnson Space Center) on 30 June 2011.
- Main Markets
-
Brazil
Germany
Singapore
Switzerland
Ukraine
- Main Product
Related Products
CAI
Optical Q™ Fluorescence Immunoassay Analyzer
One Step Sperm Concentration Test Strip/Card
POCT Fluorescent Immunoassay diagnostic System
Portable, Endoscopic visual system_QVION