Hot Cell

Hot Cell


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
hot cell, isolator, nuclear medicine, radiophamarceuticals
Category
Machinery & Parts
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

Nuclear Light Ind. Co., Ltd.

Membership
BIZ
Country / Year Established
South Korea South Korea / 1991
Business type
Manufacturer
Verified Certificate

11

DUNS

Product name Hot Cell Certification -
Category Machinery & Parts Ingredients -
Keyword hot cell , isolator , nuclear medicine , radiophamarceuticals Unit Size -
Brand name - Unit Weigh -
origin Stock -
Supply type - HS code -

Product Information

Mission Statement

 

We care about people.

Our primary goal is to protect workers and

save their families.

So, safety is the first.

 

Every single member of the firm, Nuclear Light Ind. Co. Ltd., is committed to the development of nuclear medicine devices in a bid to protect and saving lives from being harmed and contaminated by hazardous isotope materials. We Nuclear Light Ind. Co. Ltd., do believe that securing personal safety is the most valuable asset for which we stand. Our mission is therefore to give the people comfort, relief, and happiness with reliable devices produced and supplied in a sophisticated manner.

First made public in 1992 with the aim of enhancing the nuclear medicine field, Nuclear Light Ltd. started off with radiation shielding facility construction, documentary service for the approval of facilities where radiation exploration must be shielded, and supplying dose calibrators, and later extended into the development of hot cell with its subsidiary devises. And it eventually leads to one of prominent organizations to be recognized by the market as an innovative firm in S. Korea.

With nuclear medicine equipment and well established know-how - piled up over two decades - of radiation shielding technologies, NL has contributed to the industry in terms of securing radiation safety and comfort use, resulting in the industrial enhancement with the accumulated radiation technique and experience. As the industrial leader, NL is willing to provide better service and products with a step further toward clients.


 

Company Introduction

Having developed and installed the NUCLOCK series since the first installation in 1993 at the Samsung Medical Center, Nuclear Light Ind. Co. Ltd. has set up and spread the series throughout well-known hospitals such as Seoul National University Hospital, ASAN Medical Center, National Cancer Center, and You-sei University Health System along with many others in South Korea.

With gradual development of the technologies in an effort to meet global standards, Nuclear Light first exported the NUCLOCK series to Thailand Institute of Nuclear Technology in Thailand, government-run- institute, in 2011 and 2012 respectively. It is Because of IAEA that gave a special recommendation letter to the institute after NL had been recognized by the global community. Considering our endless efforts to enhance the NUCLOCK series every single day and recognition made by domestic and global communities, Nuclear Light is certain that the NUCLOCK series will be loved and make a great contribution to the industry worldwide.


 

 

NUCLOCK Hot Cell series

The NUCLOCK hot cell series are all designed to house dispensing systems and/or synthesis modules with safe, reliable, and sterile conditions. The NUCLOCK series equipped with single or double either horizontally or vertically built up is to have different configurations in regard to overall dimension, shielding capacity, and various accessories customized by an end-user.

A main structure used to support all the NUCLOCK series is of steel plate H. Beam (SS400) while the internal working area is made of stainless steel with well polished surface. And it is designed to allow for easy cleaning and decontamination.

The NUCLOCK series are all built to have a touch screen that provides clear image, easy-to-use, and ergonomics, so as to help us easily access all of the functions in a single point.

The NUCLOCK is also equipped with air tight system with acrylic glass panel held by inflatable gaskets mounted around the outline of all the entrances of cells.

Vial extraction system for the NUCLOCK series is placed on the side of a cell where it can house a vial. It is therefore possible to extract the radiopharmaceuticals without opening the main door.

The ventilated pre-chambers for the introduction of materials are mounted on either side suitable for preparing dose of radio medicines.

 

Production Hot Cell

The NUCLOCK N1 series is for radiopharmaceuticals production and performed in the safest conditions with air-tightness assured by inflatable seals, ventilation, absolute filtering and internal surfaces quality.

Specifications

 

Shielding

 

- Lead thickness: 75mm for doors, side walls (left, right, and back), top and working surface

 

Internal view

 

- View: 1 single-angle mirror

- Light: 2 LED lamps

 

Ventilation

 

- Air quality: Class B

- Inlet filter: HEPA SHLNH-6016 (Ei≥99.97%)

- Outlet filter: HEPA (Ei≥99.97%)

 

Dimension and Characteristics

 

Single cell

- External total dimensions: 1300(W) * 1200(D) * 2680(H)mm

- Inner dimensions: 850(W) * 850(D) * 850(H)mm

- Power: three phase four wire system 380V, 5Kw/ Single phase 110V, 2Kw

- Inlet air-gas

- Inlet N2 gas

 

Dual cell

- External total dimensions: 2440(W) * 1200(D) * 2500(H)mm

- Inner dimensions: 850(W) * 850(D) * 850(H)mm

- Power: 3 phase 220V

- Air: 4kg/cm2

- N2: 7kg/cm2

 

Main Door

Up-down type (Choice)

- Automatic up-down mobile door activated by motor installed inside.

 

Swing type (Choice)

- Hinged Shielding door

 

Internal sliding window

 

- Lead window dim. 350*350mm, equivalent of Pb=75mm

 

 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dispensing Hot Cell

The NUCLOCK N2 series is a hot cell designed for radiopharmaceuticals dispensing where a dispenser is installed inside a cell to carry out daily activities in accordance with the GMP standards thanks to air tight, ventilation system with HEPA filters, absolute filtering and inside surfaces quality.

 The main features are:

 Ventilation System

→     Inlet HEPA filters;

→     Outlet HEPA

→     The atmosphere pureness inside the box is assured by flat filters (both inlet and outlet) and a high quantity of air changes per hour in order to avoid any influence on the local laminar flow of dispensing unit,

Additional Accessories

→     Air-tight and minimum volume duct with double door (ball valves) for vials extraction without altering cell sterility.


Specification

 

Shielding

 

- Lead thickness: 75 mm for doors, walls (left, right, back), top and bottom

 

Internal view

 

- View: 2 wide-angle cameras; 1 colour display

- Light: 2 LED lamps

 

Ventilation

 

- Air quality: Class B

- Inlet filter: HEPA SHLNH-6016 (Ei≥99.97%)

- Outlet filter: HEPA (Ei≥99.97%)

 

Materials introduction / extraction

 

- double-door air-tight duct for vials extraction in tight condition

- extractable trolley for the lead containers extraction

 

Dimensions and Characteristics

 

- External total dimensions: 2440(W) * 1200(D) * 2500(H)mm

- Inner dimensions: 850(W) * 850(D) * 850(H)mm

- Power: three phase four wire system 380V, 5Kw/ Single phase 110V, 2Kw

- Weight: about 8000kg

- Inlet air gas

- Inlet N2 gas

 

 

Main door

 

Up-down type (Choice)

- Automatic up-down mobile door activated by motor installed inside.

 

Swing type (Choice)

- Hinged Shielding door`

 

Option

 

- Tong booting

- Hand Glove

- Prechamber

 

 

Research Hot Cell

The NUCLOCK N3 series designed for research experimentation purpose is made precisely to house synthesis modules with the highest flexibility suitable for setting up a new synthesis process.

The N3 cells are equipped with manipulation, plexiglass panel with gloves, internal sliding lead glass, air-tight transfer system with double door and lift. All above mentioned features enable to use the cell in different configurations and in particular the manipulation with front lead door opened but in air tight conditions (with plexiglass panel closed)

Ventilation System

→     Inlet HEPA filters;

→     Outlet HEPA

→     The atmosphere pureness inside the box is assured by flat filters (both inlet and outlet) and a high quantity of air changes per hour in order to avoid any influence on the local laminar flow of dispensing unit,

Specifications

 

Shielding

- Lead thickness: 75 mm for doors, walls (left, right, back), top and bottom

 

Internal view

 

- View: 2 wide-angle cameras / 1 colour display

- Glasses Monitor (connected to the TV system) for an optimal view during manipulation

 

Ventilation

 

- Air quality: Class B

- Inlet filter: HEPA SHLNH-6016 (Ei≥99.97%)

- Outlet filter: HEPA (Ei≥99.97%)

 

Accessories

 

- Lead glass window sliding inside the insulator

- Lead equivalent: 30mmPb e.g.

- Air-tight pre-chamber with double door, extractable vessel and actuated lift for material introduction/extraction

 

Dimensions and Characteristics

 

- Shielding: 75mm on all sides

- External total dimensions: 2440(W) * 1200(D) * 2500(H)mm

- Inner dimensions: 970(W) * 750(D) * 600(H)mm

- Weight: about 9000kg

- Power: three phase four wire system 380V, 5Kw/ Single phase 110V, 2Kw

- Air: 4kg/cm2

- N2: 7kg/cm2

- Vacuum: 400mmhg

 

Main Door

 

Up-down type (Choice)

- Automatic up-down mobile door activated by motor installed inside cells.

 

Swing type (Choice)

- Hinged Shielding door

 

Internal sliding window

 

- Lead window dim. 350*350mm, equivalent of Pb=75mm

 

 

Option

 

- Tong booting

- Hand Glove

- Prechambe

 

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Nuclear Light Ind. Co., Ltd.

Country / Year Established
South Korea South Korea / 1991
Membership
BIZ
Business type
Manufacturer

11

DUNS

President
Choung Youngsub
Address
40-19, Ori-ro 22da-gil, Guro-gu, Seoul, South Korea 152-883
Product Category
Beauty & Personal Care,Medical Devices
Year Established
1991
No. of Total Employees
1-50
Company introduction

 

Every member of the company is dedicated to the development of nuclear medicine equipment in the pursuit of protecting and saving lives from being contaminated by hazardous materials. We Nuclear Light Ind. Co. Ltd., hereafter called NL, do believe that personal safety is the most valuable asset that we are pursuing. Our mission is therefore to give the people comfort, relief, and happiness by producing and supplying reliable devices that are designed and developed with a sophisticated manner.

NL was founded in 1992 with the aim to enhance development of a variety of businesses related to the nuclear medicine, starting off with radiation shielding facility construction, documentation service for the approval of facilities where they produce radiopharmaceuticals, and supplying dose calibrators, and later extended into the development of the hot cell with its subsidiary devises, leading to one of prominent organization recognized by the market as an innovative firm in S. Korea.
With nuclear medicine related equipment and well established know-how - piled up over two decades - of the development of radiation shielding technologies, NL has contributed to the industry in terms of radiation safety concerns and comfort use, resulting in the industrial enhancement with the accumulated radiation technique and experience. As the industrial leader, NL is committed to providing better service by continuously putting a step further toward clients.

 

Main Markets

Jordan Jordan

Thailand Thailand

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more