Analyzer

SPTC
P-5C (Dust Analyzer)

The P-5C Particulate Monitor performs continuous, nonextractive mass concentration measurement – simply and reliably – in a wide variety of applications.

-. Single-ended, Self-aligned Instrument

Mounts to standard ASA flange, with no requirements for alignment or opposite wall access, resulting in low installation costs.

-. Ready to Operate

Complete with internal zero and reference calibrations, purge system, and protective covers.  Comes with integral purge system and protective covers. Installs in minutes, operated and calibrated by non-skilled plant personnel.

-. Rugged Design
Proven reliability for 20+ years in abrasive and/or corrosive applications.

-. Meets Regulatory Requirements
Has passed US EPA PS 11 Requirements. Ideal for CAM applications.

-. Minimal Consumables
Save time, money and inventory stocking.

-. Specifications

Measurement Range
1 – 20,000 mg/actual m3
Scale Ranges
Dual ranging, user selectable anywhere within the measurement range.
Detection Limit 0.5 mg/Am3
Stability
Zero and Span Drift
Short Term (2Hr.) – Less than 1% full scale Long
Term (24Hr.) – Less than 2% full scale
Response Time Approximately 3 seconds
Calibration
Internal system automatically performs a low level (Zero) and upscale Span cycle at intervals initiated by internal clock or by external data system command (contact closure). External calibration tube provides traceable values for reference calibrations and instrument audits.
Ambient Temperature -30°C to 55°C
Process Gas Temperature
To + 260°C standard, to + 375°C with high
Temperature probe option.
Process Gas Pressure
To + 130mm H2O standard
To + 375mm H2O w/High Volume Purge
Blower Option.
Process Gas Velocity Instrument operation is
Independent of gas velocity.
Power Requirements
110° ± 15Volts AC, 60Hz, 6A
(220V, 50Hz optional)
Output
4-20MA, 550 ohms maximum resistance.

-. Installation Information

PIPE Size:
Mounts into standard 4” (or larger) pipes
Mounting Flange
ASA standard 4”(150#) flange (9”OD, with eight, 3/4” diameter bolt holes on 7 1/2” diameter B.C.)
Probe Length
Distance from mounting flange to center of sampling volume – 18”, 36” or 60” standard
Physical Dimensions
Probe length plus 30 1/2” long x 12 1/2” wide x 18” high
Weight 125 – 140 pounds

-. Optional Equipment

  1. High Pressure Purge System
    For process gas pressures in excess of + 130mm H2O
  2. High Temperature Probe Option
    For temperatures from 260 C up to 375°C maximum
  3. Output Cable
    Complete with connector, lengths to 500 feet.
  4. Plant Air Backup

WARRANTY Twelve (12) month return-to-factory warranty.
Specifications subject to change without notice

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

SPTC., Ltd.

Country / Year Established
South Korea South Korea /
Business type
Others

16

DUNS

President
Bae, Jung-gun
Address
203-703 Buchon Techno-Park 2 BL, 192 Yakdae-dong, Wonmi District Bucheon-si Gyeonggi-do
Product Category
Measuring & Gauging Tools
Company introduction

SPTC was established on May 7th, 1999 under a mission to "protect people and the earth", and is fully committed to its mission by researching and developing environmental protection systems: factory chimney auto-examination systems to measure gas disposal and environment pollutants, auto air pollution meters, weather equipment, auto water quality examination systems, environment pollution auto detectors, and automobile gas discharge gauges.

Recently we developed a multi-purpose automobile gauge that performs as a gas discharge gauge, gas cooler, and gas meter as well as smoke meter, and export to overseas. SPTC serves many domestic and international customers, and has gained much field experience.
We at SPTC will be doing our best to protect people and the environment from contaminants. We thank you for your continuous support.

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more