X-Ray GRID

X-Ray GRID


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
South Korea
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
medical device, medical monitor, x-ray grid, health monitor
Category
Medical Devices , X-Ray Equipment
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

Wonsolution Co., Ltd.

Membership
VIP
Country / Year Established
South Korea South Korea / 2005
Business type
Manufacturer
Verified Certificate

16

TRADE TOWER

DUNS

Product name X-Ray GRID Certification -
Category Medical Devices
X-Ray Equipment
Ingredients -
Keyword medical device , medical monitor , x-ray grid , health monitor Unit Size -
Brand name - Unit Weigh -
origin South Korea Stock -
Supply type - HS code -

Product Information

X-Ray GRID




│ DESCRIPTION │


WONSOLUTION.CO offer full lines of aluminum interspaced X-ray grids of the highest and the most precise quality to the radiologist.
WONS Grids contain the purest lead available to ensure superior efficiency in removing scattered radiation.
Superior quality images are achieved through the use of aluminum inter spacers and lead strips which are precisely milled to uniformity.
Grid strips are sealed between a smooth aluminum cover and finished in enamel providing



│ THREE TYPES OF LEAD STRIP POSITIONING │


PARALLEL TYPE
In the use of a parallel grid, no matter where the tube is located, there is never a condition under which all of the strips will be aligned with the tube, since they are all vertical. Only the strips directly under the X-ray tube can be in true alignment with the primary rays. Thus there will be cut-off on the sides of the film whenever a parallel grid is used. Therefore, we generally do not make parallel grids with a ratio higher than 6:1. It is also recommended that a parallel grid not be used at any distance less than 150cm, since the lead shadows becomes smaller as the tube is moved away from grid.

FOCUSED TYPE
In a focused grid, the lead strips are tilted progressively as they move away from center. The dotted lines drawn through each of these strips converge at a point somewhere above the grid; this point is known as the grid focus. This is where the X-ray tube should be located for perfect alignment of the primary ray with each of the strips.

CRISS-CROSS TYPE
Criss-Cross
A crossed grid is actually two grids, one above the other, with the lead strips of one perpendicular to those of the other. When enclosed in a cover, these two grids become a crossed grid..



│ SPECIFICATIONS │


VARIOUS SIZES

Grid sizes correspond to available Film sizes. The grids are shipped one inch larger in each dimension, except for the standard Bucky size 17-1/4×18-7/8" Grid sizes are available in any inch sizes and metric size. Special size of Grids can be made by buyer's specification or drawings

VARIOUS DENSITY

WONS Grids are available In eight density types: 60 lines/inch (24 lines/cm), 70lines/inch (28 lines/cm), 85 lines/inch (34 lines/cm), 103 lines/inch (40lines/cm), I20 lines/inch (47 lines/cm), 150 lines/inch (60 lines/cm), 178lines/inch (70 lines/cm), 200 lines/inch (80 lines/cm).

VARIOUS RATIOS

WONS Grids ratio is the height of its lead strip Compared to the space between strips.
Superline grids are available with ratios ranging from 5:1 to 15:1

FOCAL RANGE
Short, medium and long...covering tube to film distance from 28" to infinity.
In the case of the 8:1 ratio grid, it has been made with a true focus of 38', and can be used satisfactorily from 34" to 44". With higher ratio grids it is considerably narrower. In the case of the 12:1 ratio grid, it would have a range of only 36" to 40".

x-ray Grids Aluminum inter-spaced
x-ray Grids carbon inter-spaced
mammography Grids polyester inter-spaced
Special size of Grids can be made by buyer's specification or drawings.


B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Wonsolution Co., Ltd.

Country / Year Established
South Korea South Korea / 2005
Membership
VIP
Business type
Manufacturer

16

TRADE TOWER

DUNS

President
kwag jeong won
Address
977-6, Wolchul-dong, Buk-gu, Gwangju, Korea
Product Category
X-Ray Equipment
Year Established
2005
No. of Total Employees
1-50
Company introduction

Founded in 1990, Won Solution(former Won Medical) has been developing and manufacturing X-ray equipment for around 23 years and providing the best products for customers in a timely manner.
Giving the top priority the top quality service for higher satisfaction.

Also, focusing on technology development and service provision for your health, Won Solution shall spare no effort to be the leader in the medical industry.

Products

-Development software & hardware: diagnostic radioactive ray control device, automatic film developer, unmanned alarm, vision system and software, optical communication

-Manufacturing & sales: diagnostic x-ray control device, normal type and high frequency type

-Sales of finished products: diagnostic x-ray equipment, automatic film developer, and other medical equipment

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more