Drainage Catheter

Drainage Catheter


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
Category
Medical Devices
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

Intro Health

Country / Year Established
South Korea South Korea /
Business type
Others
Verified Certificate

16

DUNS

Product name Drainage Catheter Certification -
Category Medical Devices Ingredients -
Keyword - Unit Size -
Brand name - Unit Weigh -
origin Stock -
Supply type - HS code -

Product Information

Locking pigtail drainage catheters are commonly used for the treatment of fluid drain of varied causes in the chest, abdomen, and pelvis. Predicting a successful drainage procedure is a complex and multifactorial process based on the size, location, character, configuration of the abscess and user's skill. 'KJEENA' Locking pigtail drainage catheters were designed, developed and manufacturing by INTRO HEALTH under ISO13485:2003. We can provide our specific products with finished sterile package or non-sterile bulk package underOEM base as well.

Features & Benefits

  • One touch Locking-knob is adopted for holding mono-filamentconveniently.
  • Large drainage holes designed to maximize drainage and allow debris to pass.
  • Optimal stiffness and flexibility of catheter material.
  • Excellent coating helps insertion ofthe catheter easily.
  • Ideal tapered tip ensures .smooth introduction and less patient discomfort.
  • Various Loop IDs from 0.5cm to 2.0cm or more are available.

How to use

  1. Arrow mark of Locking knob is indicated to the "Un-lock" position.
  2. When the drainage catheter is placed in the body correctly, physicians take the stylet out of the catheter and pull the mono-filament out gently until stop the pulling, which means the distal tip of catheter is fixed with catheter body in pig-tail shape in the catheter placement position.
  3. Then turn the locking knob clock-wise to the mark of "lock" to prevent from releasing of the mono-filament and firm fixation of catheter.
  4. When physician remove the catheter out of patient, just turn the Locking Knob counter clock wise to the arrow mark position of "Unlock". Then, the mono-filament will be released.
  5. Physician can take the catheter out of the patient body easily.

Ordering Specifications

Product Code

FRENCH

LO

LI

WL (mm)

TL (mm)

GDRC-071812

7F

18.0

12.0

270.0

320.0

GDRC-081006

8.5F

10.0

6.0

270.0

320.0

GDRC-081510

8.5F

15.0

10.0

270.0

320.0

GDRC-081813

8.5F

18.0

13.0

250.0

320.0

GDRC-082317

8.5F

23.0

17.0

230.0

320.0

GDRC-101811

10F

18.0

11.0

250.0

320.0

GDRC-102518

10F

25.0

18.0

250.0

320.0

GDRC-121910

12F

19.0

10.0

250.0

320.0

GDRC-122718

12F

27.0

18.0

250.0

320.0

GDRC-142010

14F

20.0

10.0

250.0

320.0

GDRC-142819

14F

28.0

19.0

250.0

320.0

PTBD-081510

8.5F

15.0

10.0

370.0

420.0

PTBD-082317

8.5F

23.0

17.0

370.0

420.0

PTBD-101811

10F

18.0

11.0

350.0

420.0

PTBD-102518

10F

25.0

18.0

350.0

420.0

LO = Loop OD, LI = Loop ID, TL = Total Length, WL = Working Length
Above specifications could be changed without any previous notice and added optionally.

Various Specifications

Type
Spec.
GDRC
7F, 8.5F, 10F, 12F, 14F
PTBD
8.5F, 10F
Stylet
Blunt, Trocar

ISO13485:2003 & Patents

ISO13485:2003
NO.11 0132 SJ
Date of issue : 25.05.2011
Valid until : 31.05.2014
For production and Distribution of Catheter
Issued by ITC
Certificate of Patent
No.10-1XX79XX
Appl. Date:07.31.2008
Reg. DateL05.24.2011
For Catheter
Issued by Korean Intellectual
Property Office
Certificate of Patent
No. 10-10XX9XX
Appl. Date:07.31.2008
Reg. Date:05.24.2011
For Catheter
Issued by Korean Intellectual
Property Office

Flexibility of Materials & Nice coating

  • Optimally flexible and kink-resistant.
  • Specifically bonded hydrophilic coating

Tip End & Holes

  • Smoothly reduced tip end
  • Large drainage holes inside curled tail

One stop locking hub

  • One stop & small size locking hub
  • Leak-proof

Stylet/Trocar with Stiffen Cannula

  • Standard blunt type and Trocar type
  • Metal stiffen cannula is assembled with

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Intro Health

Country / Year Established
South Korea South Korea /
Business type
Others

16

DUNS

President
Kim HeejJn
Address
3rd Fl., Wonil Bldg., 169-63, Sanggye-dong, Nowon-gu, Seoul 139-815, Republic of Korea
Product Category
Beauty & Personal Care,Medical Devices
No. of Total Employees
1-50
Company introduction

INTRO HEALTH has been established since October 2006 after renaming of the mother company SOOSAN GIC established in 2002.
INTRO HEALTH has been manufacturing Locking Pigtail Drainage Catheters (Multipurpose, Nephrostomy and PTBD) OEM and/or ODM base used for interventional radiology and cardiology section. Quality has been already proven in the many large general and university hospitals of over 1,000~2000 beds. We can supply customized design an special specifications with bulk, non-sterile package in oem base as well.

Main Markets

Australia Australia

Germany Germany

Italy Italy

Japan Japan

Monaco Monaco

N.Zealand N.Zealand

Saudi Arabia Saudi Arabia

U. Kingdom U. Kingdom

U.A.E. U.A.E.

U.S.A U.S.A

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more