Waste Heat Recycling Fan

Waste Heat Recycling Fan


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
heat recycling fan, high-efficiency equipment, reduced energy, waste heat recycling fan
Category
Machinery & Parts , Energy Saving & Fluorescent
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

Servan

Membership
VIP
Country / Year Established
South Korea South Korea / 1993
Business type
Manufacturer
Verified Certificate

11

DUNS

Product name Waste Heat Recycling Fan Certification -
Category Machinery & Parts
Energy Saving & Fluorescent
Ingredients -
Keyword heat recycling fan , high-efficiency equipment , reduced energy , waste heat recycling fan Unit Size -
Brand name - Unit Weigh -
origin Stock -
Supply type - HS code -

Product Information

Waste Heat Recycling Fan

New: Obtained certification "high-efficiency equipment" for waste heat fecycling Fan

l Summary l

Reduced energy cost
The subject unit makes possible energy cost reduction and smooth ventilation, preventing energy loss by ventilation and preserving a certain degree of indoor energy.
Thus, it is frequently said that the subject unit is a perfect ventilation system to create comfortable indoor environment by inputting fresh O.A as it is the best choice to be able to use in complete harmony with A/C Unit.

Customers' inconvenience cleared up by simple maintenance.
The subject unit was so designed that they could remove mechanical parts within 5 minutes. And Heat recycling wheel was so manufactured that they could make simple maintenance and operation, with belt-driven system installed in motor to prevent wear and shock and absorb vibration.

Perfect warrant and service
We warrant the subject unit to be free of problems for 5 years after the date of purchase and so is energy-recycling heat source wheel.
We take great pride in this product and promise you to give perfect A/S.

Suggested applications

  1. House, Deluxe Villa, Apartment, School
  2. Office, Computer room, Resting room, Smoking Room, Negotiating room
  3. Underground shopping center, restaurant



l Features l

  1. Prompt discharge of indoor polluted stuffs and supply of fresh O.A
  2. The keeping of indoor comfortable relative humidity.
  3. Outstanding ventilation effect by two-way ventilation system.
  4. Possible to preserve a certain degree of indoor temperature when ventilating.
    (Reducing cooling and heating energy)

Energy saving effect
Energy saving effectReviewed economical efficiency on case-by case basis after establishing cooling & heating and indoor & outdoor air condition as follows




1. Energy saving effect of the existing waste heat recycling FAN

(1) Recycling heat quantity when cooling down and heating up

  1. when cooling down : 200×1.2×(21.5-12.6)×0.62 = 1,324 kcal/h
  2. when heating up : 200×1.2×(10.3-0.8)×0.62 = 1,414 kcal/h

(2) Annual recycling heat quantity

  1. when cooling down : 1,324×2880 = 3,813,120 kcal
  2. when heating up : 1,414×3900 = 5,090,400 kcal

3)Annual total recycling heat quantity = 8,903,520 kcal



2. Energy saving effect of our waste heat recycling FAN

(1) Recycling heat quantity when cooling down and heating up

  1. when cooling down : 200×1.2×(21.5-12.6)×0.8 = 1,709 kcal/h
  2. when heating up : 200×1.2×(10.3-0.8)×0.95 = 2,166 kcal/h

(2) Annual recycling heat quantity

  1. when cooling down : 1,709×2880 = 4,921,920 kcal
  2. when heating up : 2,166×3600 = 7,797,600 kcal
3)Annual total recycling heat quantity = 12,719,720 kcal

3. ompared recycling heat quantity

Codition
Existing product(kcal)
Relative huidity(%)
Increase rate(%)
Recylcling heat quantity when cooling down and heating up
3,813,120
4,921,920
29.1
Recylcling heat quantity when cooling down and heating up
5,090,100
7,797,600
53.2
Annaul recycling heat quantity
8,903,520
12,719,720
43


Because recycling heat quantity increase rate of our product is much higher  than that of existing product in comparison of recycling heat quantity, the users can enjoy improved energy saving effect.

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Servan

Country / Year Established
South Korea South Korea / 1993
Membership
VIP
Business type
Manufacturer

11

DUNS

President
John Jeong
Address
27, Hwajeonsandan 5-ro, Gangseo-gu, Busan, Korea
Product Category
Refrigeration & Heat Exchange Machinery
Year Established
1993
No. of Total Employees
51-100
Company introduction

 

 Servan values customer satisfaction and aftercare service as the top priority. We aim to provide conduct maintenance and inspection that our customers can trust, and to make sure our products are in operation with their optimal efficiency at all times.

We haven taken one step further by introducing ‘beforecare service,’ in which Servan agents will reach our customers periodically before a real problem occurs. Servan’s strict policy in considering our customers as the top priority also represents our responsibility and confidence for our products.

 

Main Markets

Russia Russia

Saudi Arabia Saudi Arabia

Factory Information

SERVAN

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more