Gas detector (DA-800 Series)

Gas detector (DA-800 Series)


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
gas detector, gas sensor, combustible, fixed
Category
Sensors
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

GasDNA

Membership
VIP
Country / Year Established
South Korea South Korea / 2004
Business type
Manufacturer
Verified Certificate

11

DUNS

Product name Gas detector (DA-800 Series) Certification -
Category Sensors Ingredients -
Keyword gas detector , gas sensor , combustible , fixed Unit Size -
Brand name - Unit Weigh -
origin Stock -
Supply type - HS code -

Product Information

DA-800 detects various combustible, toxic and VOC gases leaked from industrial areas and display its density for gas producers, gas users, gas reservoirs, gas by-producers, and so on.

It is an indicator and transmitter type gas detector which converts detection signal into a standard current signal and transmit output to external devices.

Transmitter of DA-800 displays sensor’s current and voltage signal by gas density on LCD, still converts into 4-20mA standard current output signal and transmit to external side.

4-20mA standard current output signal can be transmitted to various controller such as Gas leakage alarm system (GMS1000, GMS2000) PLC, DDC, MMR to build a integrated or individual gas monitoring system.

[Specification]

 

Segment

DA-800

  Gas sampling

Suction type

Density display

 LCD Display - PPM, %LEL , %  (set by user)

Input power

 DC 20~30V

Structure

 Explosion proof

Target gas

 Toxic, Combustible , O2, VOC(PID)  (select)

Detection principle

 Catalytic, Electro-Chemical, VOC(PID) ,NDIR (select)

Suction flow rate

 0 ~ 1000ml/ min

Suction distance

Within 100m

Measurement range

Please refer to the target gas list (page 16)

Accuracy

£ ±2%/Full Scale

Response time

Within 20 seconds, 90% / full scale

Sensor calibration

AUTO-CALIBRATION with Magnetic Switch

User programming

Calibration density & Measurement range

Wiring

CVVS & CVVSB 1.25sq*3wire

Output signal

 4-20㎃ DC/F.S // RS-485(MODBUS-RTU)

Alarm output

  2 Step (HIGH/LOW) Alarm RELAY CONTACT

Operation Temperature

  -10℃ ~ 50℃

Operation humidity

 5 ~ 95%RH (Non-Condensing)

Wire conduit

1/2” or 3/4” PF,NPT

Housing material

  Cast Aluminum Alloy

Mounting

Wall or Pipe Station

Product Info Attached File

DA-800.pdf

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

GasDNA

Country / Year Established
South Korea South Korea / 2004
Membership
VIP
Business type
Manufacturer

11

DUNS

President
GO SUNG-WOON
Address
C-910C, Bupyeong woolim lion's valley, cheongcheon-dong, Bupyeong Gu, Incheon, Korea
Product Category
Sensors,Smoke Detector,Temperature Instruments
Year Established
2004
No. of Total Employees
1-50
Company introduction

GasDNA Co.,Ltd is a professional and leading manufacturer of Fixed Infrared thermometers, Gas detectors and smoke detectors

for use in a various kinds of industries.

GasDNA is focusing on developing and distributing more convenient and stable gas detectors and infrared thermometers.

Based on the technologies and expertise accumulated for last 10 years, we have positioned as Korea's only infrared thermometer

manufacturer, and we are planning to expand into not only the domestic market but overseas markets.

We develop and manufacture efficient and reliable products based on state-of-the-art technologies, and we do our best to be the world's leading company in the gas detector and Infrared thermometer field.

We promise customer's safety and product quality in accordance with the quality assurance K mark and ISO9001 quality system to maximize the customer's use value.

 

Gas detectors detect one target combustible or toxic gas leaked from industrial sites for in order to prevent any accidents in advance. And it converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on. Using these functions, you can easily construct the gas monitoring system more extensive as well as more comprehensive.

Infrared thermometer measures a surface temperature by non-contact through measuring the infrared wavelength emitted from the target spot and converts it to standard current signal output (4~20mA) and RS-485 communication signal output. we have a various tempearture ranges upto 2400degreeC and compact and precision type, also can choose fixed and portable type.

Main Markets

Taiwan Taiwan

Factory Information

GasDNA

Main Product

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more