Induction high bay fixture,Electrodeless lamp,LVD flood light

Induction high bay fixture,Electrodeless lamp,LVD flood light


Negotiable Min Order Quantity Unit

Required Quantity
Place of Origin
Payment Terms
Negotiable
Production method
Negotiable
Shipping / Lead Time
Negotiable / Negotiable
Keyword
induction lamp, electrodeless lamp
Category
LED Lighting
tK Meet
tK Meet

Apply a video call to the Supplier

SEND TO SUPPLIER INQUIRY

Vdeen Lighting Co.,Ltd

Country / Year Established
China China /
Business type
Others
Verified Certificate

14

Product name Induction high bay fixture,Electrodeless lamp,LVD flood light Certification -
Category LED Lighting Ingredients -
Keyword induction lamp , electrodeless lamp Unit Size -
Brand name - Unit Weigh -
origin Stock -
Supply type - HS code -

Product Information

Electrodeless Hi Bay Lighting and Plant Grow Light 
  125 watt, 150 watt, 165 watt
For exchange information and market survey only


  Some of the main characteristics include:
1. Long lamp life of 60 000 hours (four times the normal service life of conventional fluorescent lamps)
2. High luminous efficacy of 80 lumens/watt
3. Instant flicker-free start; and
4. Excellent quality of light and high luminous flux.

How does it work
The high frequency electrodeless discharge lamp is made of three parts: 1. the lamb bulb, 2. the coupler 3. the high frequency power supply generator. When the power goes through the high frequency power supply generator, it creates a 2.65MHz high frequency positive power. It uses the principle that electromagnetism is coupled into the lamp bulb it responds to make the air in the bulb avalanche the electricity to form plasma. When the stimulated atoms of the plasma returns to its base state, the plasma radiates at the wavelength 254nm .Ultraviolet light is emitted which in turn excites the phosphors to create almost instantaneous light.

Best practice design and technology information
Mercury high discharge lamps
Mercury high discharge lamps are widely used in warehouses, factories and gymnasiums with high ceilings. They have a low initial cost but poor efficiency overall. In addition, they create significant disposal problems as a result of their use of the heavy metal mercury. In most situations, mercury lamps can be replaced by metal halide lamps with much improved efficiency.

Electrodeless lamps
In contrast to conventional fluorescent lamps, the electrode-less lamp generates light without electrodes in a closed 'ring' with no starting point and no end point. The energy is 'injected' via ferrite rings from outside using magnetic fields (induction principle). The lamp therefore has no points that can wear out, and last longer than conventional lamps.

Features
Long life and low degradation:
Because there is no filament or electrode, the life span will be more than 60,000 hours and Up to 100,000 hours, the average degradation rate is <5%.

High efficiency and energy saving:
High efficiency, it achieves ≥63 Lm/w,the power factor is more than 0.98, cosφ≥0.98, lamp power consumption ≤ 0.02 input ≈output, high frequency electrode-less discharge lamp 100W is equiv to a 600W incandescent light, under normal circumstances an 85W high frequency electrode-less discharge lamp ≈170W Metal Halide ≈250W, high pressure sodium ≈500W incandescent.

Environmental protection:
It uses encapsulated mercury, when the bulb breaks, it will not cause pollution, also it only contains 3mg mercury, while the other lights contain 14 mg mercury 99% recyclable, the whole high frequency electrode-less discharge lamp is 99.6% recyclable.

No flickering, low glare, good for eyes:
Because of high efficiency and no flickering, the light is very stable, bright, low glare.

High dependability:
The product is available in both AC and DC models. The AC voltage is in the scope from 110V to 264V, and the DC in 12 + 24 volt. The environmental temperature is between -30 to +50C.

Moment start, no warm up require:
The function of start and restart is excellent, and it will not cause light degradation:

High colour rendering index:
colour rendering index is ≥80, various colours can be chosen from 3500K-6500K

No radiation pollution:
The product passes the national EMC test, it does not create stray radiation pollution.
It matches the international EMI standard EN55015and GB17743-1999 national standard,
it also passes the Europe C.E testing

Easy to install:
It is suitable in any orientation/direction and has strong anti-vibration properties.

The energy saving table
Based on 10 hours per day, and $0.12 per KW, the high pressure mercury ballast itself consumes more than 15% of the power has not been considered.

High Frequency Electrodeless discharge lamp
60,000 hours To Replace  Yearly Saving per Light  Replacement Saving  Co2 emission reduction
Base on Qld
1 KW = 1 Kg CO2 
KW Amount Parts Labour Reduce per Year  Reduce per Light 
BI 125W  250W Metal halide
 465.25 $54.75 3 times  3 times  465.25kg 1395.75kg
BI 165W  400W Mercury Vapor 857.75 $102.93 3 times  3 times  857.75kg 2627.25kg

How does Electrode-less Lamp compare to other lights Lamp Type  LPW Rated Hour  CRI Ignition Time  Color Temp  Major Drawback 
Incandescence 11-15 1.5K - 5K  40 Instant 2800 Very Inefficient, Short Life 
Mercury Vapor  13-48 12K - 24K    2 - 15min  4000 Inefficient
HPS 45-110 12K - 24K  25 2 - 15min  2000 Low CRI 
LPS 80-180 10K - 18K  0 2 - 15min  1800 Low CRI 
Metal Halide  60-100 10K - 15K  75 2 - 15min  3000-4300 High Maintenance 
Induction Lamp  61-76 60K - 100K  82 Instant 2600-6500 Higher Initial Cost. 

  ELECTRODELESS TESTING DATA
Australia in house testing

Electrodeless vs CFL vs Mercury Vapour
Electrodeless (ESL) E165w, 150w VS (CFL) 200w/120w VS Mercury Vapour (MV)400w
* Lamp height fixed 5mtrs above ground test level
* All readings taken at ground level directly under luminaries
( Test conducted at night when high line input V occurs. Generally line V may be 235VAC )

Type of Globe  Identify Globe claim in Watts >  Identify Operating Consumption >  Identify Start up Power Consumption  Identify Actual Lux at ground Level 
MV400 (New)  400W  452W  900W  270
MV400 (Aged)  400W 450W 900W 150
CFL120 (New)  120W 126W 90W 60
CFL200 (New)  200W 175W 130W 90
Electrodeless 150 (New)  150W 148W 130W 199
Electrodeless 165 (New)  165W 165W 126W 275


*NB:  Minimum Lux spread at ground level in General warehouse situation should be 160


Type Suggested
Usable Life
 New / Aged
Lumen Output / Lm Watt  Mercury Content (approx)  Strike Time 
Mercury Vap (MV)  20,000 hrs  New: 13,840 / 30.75Lw
Aged: 7,688 / 17.08Lw  14mg Delayed
Electrodeless (ESL)  60,000 hrs -
100,000 hrs
 New: 10,200 / 68 Lw
Aged: 9,180 / 61.2Lw  3mg Instantaneously

Hi-Bay ESL -E165 watt compared to MV 400w ( 450w ) as per previous table
Savings Achieved: Tube/Watts Tube Quantity  Operating Hours  KWH Saved  Savings @ 12c per Kw/h  Greenhouse Gas Emissions 
Electrodeless 165W (126W) 100 units  12hr/day,365days  124,830Kw/h $14,980 pa  In QLD: 124.83 tonnes pa
In VIC: 174.72 tonnes pa 

One globe operating 12hours per day, 365 days savings = 1248.30 Kwh/globe
GHG emission approx Queensland rate 1.0 kg per Kwh, at Victoria rate 1.4 kg per Kwh
*NB : Our electricity supply in QLD cost 15c / Kwh. 20%-25% increase in cost is forecast 2009.


Summary of results:
Mercury Vapor (MV):
Reveals very high energy use, complies with regulatory lux levels when new. however degradation is extremely rapid., In terms of compliance it means more frequent replacement & additional recurring costs. Effectively use of such globes is not only unsustainable, it is environmentally irresponsible !!

CFL:
Do provide savings & are environmentally responsible, though insufficient Lux Levels may prohibit use in regulated industrial/commercial application, they may otherwise be used where flexibility of lux level applies and/or in residential developments.

Electrodeless operating cost/savings:
Operating electrodeless lamps comapred to mercury vapour lamps may lead to >70% savings in GHG emission and similar value of dollars saved.

E150:
The manufacturer claims electrodeless lamps may degrade by upto10% over a 60,000hr - 100,000hr life, whilst still achieving regulatory or required lighting levels. Thus they are clearly superior and essentially the only responsible choice specifically so in most high-bay or industrial applications and/or elsewhere.

Tests conducted in house under the direction of Spek
Location: Rocklea, Brisbane
Date: 01 Feb 2008
Test Equipment:
1. Digitech QM 1586 Light Meter
2. Digitech QM 1520 RMS Meter
3. Mico Digital Power Energy Meter

For minor road street lighting replacing MH 80w with electrodeless 3300 lumen, 50 watt lamp with electronic ballast would reduce current power consumption (80W plus ballast loss to ~50 watts), but increase light output, also for cost savings, ballast/bulb combo can be ready fitted to a variety of existing luminaires. The main benefit is the extremely long life 60,000 - 100,000hours approx 4 times longer than T5, also 5-10% maximum depreciation over life span, is minimal in comparison to mercury vapour with ( loss up to 40% after only 10,000 hours )

Reduces installation, running & maintenance costs, and the quantity of the mercury, (75% over existing lamps). The mercury is also safety encapsulated to prevent environment pollution if lamp is accidentally broken. A 50% reduction of electricity usage for street lighting in Australia could be one of the largest single greenhouse gas strategies attempted. Savings should also include the costs of replacing lamps with far less frequency ~ 10-15 years life span.
  Compare high frequency electrodeless discharge lamp and the other lights commonly used. Light Source  W LM/W Life Hours Ra Start Restart P factor  Flicker
Electrodeless 40 - 165  63 - 80  60000 88 Instant Instant 0.98 no
Incandescent 10 - 100  6.5 - 19  1000 95 - 99  Instant Instant 1 not noticeable 
Fluorescent 6 - 125  25 - 67  12000 - 15000  70 - 80  1-3sec Instant 0.4-0.9 Obvious
High Pressure Mercury  50 - 1000  30 - 50  20000 30 - 40  4-8min 5-10min 0.44-0.67
Hid Tube  1500 - 100000  20 - 37  5000 - 10000  90 - 94  1-2sec Instant 0.4-0.9
High Pressure  250 - 400  90 - 100  25000 20 - 25  4-8min 10-20min 0.44
Metal Halide  400 - 1000  60 - 80  20000 65 - 85  4-8min 10-15min 0.6-0.9

Electrode-less lamps and luminaries are available in a wide range of
colour temperatures (2400K – 6400K) and sizes from 40 – 165 Watt (2600 – 13000 lumens). For
Flood lighting
Street lighting
Hi Bay factory lighting
Horticultural growth

Electrode-less generate minimal heat allowing lights to be lowered if extremely intense light is required.(e.g. workbench, horticulture, lathe work...etc.).
Allowing an even more extreme reduction in power costs

 

B2B Trade

Price (FOB) Negotiable transportation -
MOQ Negotiable Leadtime Negotiable
Payment Options Negotiable Shipping time Negotiable

Vdeen Lighting Co.,Ltd

Country / Year Established
China China /
Business type
Others

14

Related Products

Other buyers also search

Membership Grade

BUYER

Biz Pro VIP

SELLER

Biz Pro VIP
팝업닫기
Live Chat A new message arrives
from a business partner.

No Data

  • There is no data to load
  • Check out the My tK > My Inquiries list.
  • After agreeing to the use of the Live Chat service, the list is printed only when there is at least one history of receiving or sending a Live Chat request.

If you have not yet agreed to use the Live Chat service,

You can use the Live Chat freely after agreeing to the use of the Live Chat service.

View more
View more